Project News
[/et_pb_text][et_pb_text _builder_version=”3.20.2″ text_font=”Karla||||||||” text_font_size=”18px” text_line_height=”1.8em” header_font=”Cormorant Garamond||||||||” header_font_size=”56px” header_font_size_tablet=”40px” header_font_size_last_edited=”on|tablet” header_line_height=”1.4em” max_width=”600px” locked=”off”]K-Villa+ awarded LOTUS Gold green building certification
Green building certification, the first in Can Tho, recognizes the project team’s efforts to create a healthy living environment while respecting the harmony with nature.
[/et_pb_text][et_pb_button button_text=”Learn more about LOTUS Homes” background_layout=”dark” _builder_version=”3.20.2″ custom_padding=”10px||10px|” custom_button=”on” button_text_size=”13px” button_text_color=”#ffffff” button_bg_color=”#c2ab92″ button_border_color=”#c2ab92″ button_border_radius=”0px” button_letter_spacing=”2px” button_font=”Karla|700||on|||||” button_letter_spacing_hover=”2px” locked=”off” button_url=”http://vgbc.vn/en/lotus-en/lotus-homes/” url_new_window=”on” /][/et_pb_column][et_pb_column type=”1_2″][et_pb_text background_layout=”dark” _builder_version=”3.20.2″ text_font=”Karla||||||||” text_font_size=”18px” text_text_color=”rgba(255,255,255,0.7)” text_line_height=”1.8em” header_2_font_size=”40px” header_2_line_height=”1.4em” header_3_font=”Cormorant Garamond|600|||||||” header_3_line_height=”1.4em” max_width=”600px” locked=”off”]Details
- Rating System : LOTUS Homes V1
- Building type : Private Villa
- Size (GFA) : 813 m2
- Certification Date: September 2020
- Green consultant: GreenViet
[/et_pb_text][/et_pb_column][/et_pb_row][/et_pb_section][et_pb_section bb_built=”1″ background_color=”#121212″ _builder_version=”3.0.106″ custom_padding=”0|0px|100px|0px” prev_background_color=”#ffffff”][et_pb_row custom_margin=”|||” _builder_version=”3.0.106″ animation_direction=”bottom”][et_pb_column type=”4_4″][et_pb_image src=”http://vgbc.vn/wp-content/uploads/2020/09/K-villa-LOTUS-Gold.jpg” _builder_version=”3.20.2″ custom_margin=”-160px|||” custom_margin_tablet=”0px|||” custom_margin_last_edited=”on|tablet” animation_style=”slide” animation_direction=”bottom” animation_intensity_slide=”6%” animation_starting_opacity=”50%” /][/et_pb_column][/et_pb_row][et_pb_row _builder_version=”3.0.106″][et_pb_column type=”1_2″][et_pb_image src=”http://vgbc.vn/wp-content/uploads/2020/09/Kvilla05.jpg” _builder_version=”3.20.2″ custom_margin=”|||” custom_margin_tablet=”0px|||” custom_margin_last_edited=”off|desktop” animation_style=”slide” animation_direction=”bottom” animation_intensity_slide=”6%” animation_starting_opacity=”50%” /][/et_pb_column][et_pb_column type=”1_2″][et_pb_image src=”http://vgbc.vn/wp-content/uploads/2020/09/Kvilla07.jpg” _builder_version=”3.20.2″ custom_margin=”|||” custom_margin_tablet=”0px|||” custom_margin_last_edited=”off|desktop” animation_style=”slide” animation_direction=”bottom” animation_intensity_slide=”6%” animation_starting_opacity=”50%” /][/et_pb_column][/et_pb_row][et_pb_row custom_padding=”50px|40px|50px|40px” custom_margin=”50px||50px|” background_color=”#1b1b1b” padding_3_tablet=”|||” padding_2_phone=”|||40px” padding_3_phone=”|||40px” padding_2_last_edited=”off|desktop” padding_3_last_edited=”on|tablet” _builder_version=”3.0.106″][et_pb_column type=”1_2″][et_pb_text background_layout=”dark” _builder_version=”3.20.2″ text_font=”Karla||||||||” text_font_size=”18px” text_text_color=”rgba(255,255,255,0.7)” text_line_height=”1.8em” header_2_font=”Cormorant Garamond||||||||” header_2_font_size=”40px” header_2_line_height=”1.4em” max_width=”600px” locked=”off”]
Project Sustainability
[/et_pb_text][et_pb_divider color=”#c2ab92″ show_divider=”on” divider_weight=”2px” _builder_version=”3.2″ max_width=”50px” /][et_pb_text background_layout=”dark” _builder_version=”3.20.2″ text_font=”Karla||||||||” text_font_size=”18px” text_text_color=”rgba(255,255,255,0.7)” text_line_height=”1.8em”]Energy:
- Effective passive design with limited east and west facade areas and shading on most glazing areas
- Efficient air-conditioning systems with a COP improvement of 36.8% over QCVN 09:2013/BXD requirements
- Use of efficient LED lighting fixtures to achieve a LPD of 3.75 W/m2
- All appliances installed are energy-efficient (4 or 5 stars under VNEEP label, EU energy label class A++, etc.)
- Domestic hot water is supplied by a solar water heating system
- Solar PV system with a peak power of 15.8 kWp
Water:
- Use of dual flush low-flow WCs (3/4.5 liters per flush)
Health and Comfort
- Fresh air supply fans are installed to provide sufficient fresh air in 95% of the habitable space.
- All paint, coating, adhesive and sealant products used have low-VOC content
- All habitable spaces are provided with good daylight
Material:
- All windows and doors are made of recycled materials (uPVC with 30% recycled content and steel)
Site and Environment:
- 34.8% of the site area is covered with vegetation (with 27 different species, mostly native and climate-adapted) and pot plants installed on all the balconies and roofs
- 56.3% of average site perviousness thanks to use of open-grid pavement, green roof and unbound pavers
- during construction, measures were implemented to recycle construction waste, minimize construction noise, limit air, land and water pollution impacting the neighborhood