Dong Tien Garment Factory 3
Trang Bom, Dong Nai
General Information
- Rating System: LOTUS NR V2.0
- Building type: Factory
- Size (GFA): 16,670 m2
- Owner: Dong Tien Joint Stock Company
- LOTUS AP: GreenViet Consultancy Co., Ltd.

Garment Factory 3 has integrated a wide range of energy and water saving features. Passive Design techniques were applied, including limiting west and east orientation, reducing window-to-wall ratio (only 13.29% of WWR on east/west facades) and maximizing natural ventilation for the canteen building. Low-E glazing was installed for office area with SHGC = 0.55 and corridor was used as buffer between glazed façade and office rooms to limit solar radiation through the building envelope.
LOTUS Scorecard
Total Point: 90/110
LOTUS Platinum

ENERGY: 25/31
Improve and monitor the energy consumption of a building through proper insulation, the use of natural ventilation and the installation of energy efficient equipment

WATER: 12/13
Reduce water consumption of a building through the use of water efficient fixtures, rainwater harvesting and water reuse & recycling

MATERIALS: 4/9
Reduce the use of high embodied energy materials; Maximize the use of reused & recycled materials; Encourage a wider use of prefabricated components

ECOLOGY: 4/9
Protect the building environment and the ecology of the surrounding area; Assure the preservation of topsoil together with the maximization of biodiversity

WASTE & POLLUTION: 7/8
Promote the reduction of waste during the construction and operation of the building, as well as encourage extensive recycling practices

HEALTH & COMFORT: 12/14
Ensure a proper indoor environmental quality through maximizing daylight and open views and the optimization of the indoor air quality

ADAPTATION & MITIGATION: 7/10
Ensure that all necessary adaptation and mitigation components are integrated at the design stage of a building and to reduce the impact on the environment in terms of GHG emissions

COMMUNITY: 4/6
Promote social integration of the building within its neighborhood through public consultation, respect for cultural heritage and to facilitate access for people with disabilities

MANAGEMENT: 7/10
Ensure that all targets set up for the various stages are competently and effectively managed throughout the project

INNOVATION: 8 points
Innovative techniques/initiatives as well as exceptional performance enhancement
Green Features
- Energy use reduction: 60%
- Total water use covered by rainwater and reused treated wastewater: 67%
- Reduction of water use through fixtures: 40%
- Roof & paved area limits heat island effect: 61%
Solar panels generate an average of
- Vegetated area: 26.5%
- Paints, coatings, adhesives, sealants, floorings, composite wood with low-VOC content: 100%