[et_pb_section bb_built=”1″][et_pb_row][et_pb_column type=”4_4″][et_pb_text _builder_version=”3.20.2″]

LOTUS Interiors:E-2 Artificial Lighting

 

Intent

To reduce energy consumption associated with the use of interior artificial lighting systems.

 

Requirements

Criteria

6 points

Strategy A: Lighting power density reduction

Lighting power density surpasses QCVN 09:2013 requirements by 10 %

1

1 point for every additional 10% improvement of the lighting power density compared to VBEEC requirements (up to 50%)

5

Strategy B: Lighting controls for separate spaces

Project meet QCVN 09:2013 requirements on Lighting controls for separate spaces

1

Strategy C: Lighting controls for daylit areas

Install lighting control devices for the lighting fixtures located in potentially daylit areas

1

Strategy D: Other lighting controls

Implement the following strategies:

–       Task lighting

–       Main switch or scheduling

1

 